Product Portfolio · 13 Models Across 6 Boundary Categories

Find the Right Detection for Every Part of Your Perimeter.

Start with the boundary you need to defend—not a one-size-fits-all sensor pitch. Compare 0 W mechanical taut-wire barriers, fence-mounted fiber and locating cable, concealed ground routes, open-gap microwave links, submerged culvert grilles, and sensor-integrated lighting.

Already have a shortlist? Request model specifications or send a boundary layout for a preliminary zone proposal and equipment supply quote.

Flagship Barrier Line
0 WPerimTaut mechanical post detection with on-site pull thresholds
Complete Portfolio
13 ModelsMatched to barriers, existing fences, ground, gaps, and drains
Boundary Navigation
6 CategoriesOrganized by where you mount and what threat you face
Actionable Reporting
3 Alarm ModesZone sectors, meter-level coordinates, or nearest-luminaire ID
Fig. 02.0 — Six perimeter boundary zones and their matching detection families: (01) PerimTaut taut-wire barriers, (02) fence and wall-top sensors, (03) open-corridor microwave links, (04) buried RF corridors and discrete pressure surfaces, (05) submerged culvert grilles, and (06) sensor-integrated fence lighting.
Fig. 02.0 — Six perimeter boundary zones and their matching detection families: (01) PerimTaut taut-wire barriers, (02) fence and wall-top sensors, (03) open-corridor microwave links, (04) buried RF corridors and discrete pressure surfaces, (05) submerged culvert grilles, and (06) sensor-integrated fence lighting.

01 — Browse by boundary task

Start with the Boundary. Follow the Detection Path.

Categories group models by where they mount on site—while each model uses a distinct physical mechanism inside that category.

Parallel taut-wire array and razor-wire coil both transferring breach force to a 0 W mechanical post detector.
Parallel taut-wire array and razor-wire coil both transferring breach force to a 0 W mechanical post detector.

01 / 2 MODELS

Make the Barrier Detect — Taut-Wire Systems

Unite physical entry resistance with 0 W mechanical post detection. Choose parallel barbed wires (TW-100) or monitored razor coils (TW-150) for freestanding lines and wall tops.

Explore this category →
Three distinct fence/wall mechanisms: concealed rail fiber, mesh-attached cable/fiber, and wall-top narrow electrostatic field.
Three distinct fence/wall mechanisms: concealed rail fiber, mesh-attached cable/fiber, and wall-top narrow electrostatic field.

02 / 5 MODELS

Instrument Fences and Walls — Fence Detection Systems

Build optical sensing inside architectural rails (FF-200), attach locating or zoned fiber and vibration cable to existing fences (FO-700, FO-750, VC-600), or raise a narrow electrostatic field (EF-350).

Explore this category →
Spindle-shaped volumetric microwave corridor shown in permanent post-mount and portable tripod-mount configurations.
Spindle-shaped volumetric microwave corridor shown in permanent post-mount and portable tripod-mount configurations.

03 / 2 MODELS

Seal the Open Corridor — Outdoor Microwave Sensors

Span vehicle gates, hangar aprons, and rooftop approaches with a volumetric microwave beam. Select permanent 12–48 VDC links (MW-400) or battery-powered tripod kits (MW-450M).

Explore this category →
Side-by-side contrast between BF-300 buried twin-cable volumetric RF field and PM-280 discrete pressure-sensing surface.
Side-by-side contrast between BF-300 buried twin-cable volumetric RF field and PM-280 discrete pressure-sensing surface.

04 / 2 MODELS

Keep Protection Out of Sight — Ground and Surface Sensors

Establish a continuous ±1 m locating RF corridor beneath soil, paving, and shallow waterways (BF-300), or monitor defined footsteps on concealed pressure pads, mats, and modules (PM-280).

Explore this category →
Cross-section of an underwater FF-250 stainless grille blocking culvert entry while routing fiber to a dry-bank processor.
Cross-section of an underwater FF-250 stainless grille blocking culvert entry while routing fiber to a dry-bank processor.

05 / 1 MODEL

Close the Underwater Route — Culvert Security Grilles

Block culverts, storm drains, tunnels, and shafts with custom stainless-steel grilles (FF-250) that detect prying, bar cutting, and panel removal while fully submerged.

Explore this category →
Three fence-mounted LP-500 luminaires with the attacked unit firing directed light and sending an encrypted wireless alert.
Three fence-mounted LP-500 luminaires with the attacked unit firing directed light and sending an encrypted wireless alert.

06 / 1 MODEL

Sense and Illuminate Together — Perimeter Security Lighting

Catch fence cutting, climbing, and lifting via luminaire accelerometers (LP-500), trigger instant 53 lux light or strobe at the breach, and report over AES-128 wireless mesh.

Explore this category →

02 — Flagship passive mechanical barriers

Put the Physical Barrier Itself on Watch.

PerimTaut unites high-tensile physical deterrence with 0 W mechanical post detection—completely immune to substation EMI and RFI. On-site adjustable pull thresholds filter out animal and plant contact, while internal self-compensating mechanics absorb slow seasonal thermal shift and minor ground settlement. Built on the physical properties of its materials, the core sensing structure rarely suffers damage while protective materials remain intact, keeping routine upkeep minimal. Competitive same-tier pricing and fast factory dispatch keep high-security perimeters on budget and on schedule.

Barrier + Sensor in One

Resists climbing and cutting while actuating alarms in ≤0.5 s

On-Site Pull Threshold

Filters animal and plant contact; self-compensates thermal drift

0 W at Every Post

Zero field electronics, zero post batteries, immune to EMI/RFI

Minimal Core Upkeep

Material-based mechanics plus competitive pricing and fast dispatch

TW-100 tensioned barbed wires transfer climb or cut force to 0 W post switches while mechanical self-compensation absorbs slow thermal shift.
TW-100 tensioned barbed wires transfer climb or cut force to 0 W post switches while mechanical self-compensation absorbs slow thermal shift.

PerimTaut TW-100 · Parallel Taut-Wire Fence

9–20 cm barbed-wire array, 1–2 sensing wires per detector, 60 m typical zone, freestanding or wall/fence-top mounting.

Explore TW-100 →
TW-150 tensioned sensing wire monitors coil pulling and cutting at 0 W, with an inset showing optional internal anti-cut wire for individual loops.
TW-150 tensioned sensing wire monitors coil pulling and cutting at 0 W, with an inset showing optional internal anti-cut wire for individual loops.

PerimTaut TW-150 · Monitored Razor-Wire Coils

1–3 wall-top coil layers or freestanding barriers, 1 sensing wire per detector, plus optional single-loop anti-cut wire.

Explore TW-150 →

03 / ALL 13 MODELS

One Boundary Task. A Clear Model Choice.

01

Taut-Wire Barriers

2 MODELS
Anchor / Spiral / Detector Posts · 0 W Detector (1–2 Wires)
Anchor / Spiral / Detector Posts · 0 W Detector (1–2 Wires)

PerimTaut TW-100

A Fence That Senses the Force of Entry

Unite a high-tensile barbed-wire barrier with 0 W mechanical post switches. Set the pull threshold on site to filter animal and plant contact, and catch climbing or cutting in ≤0.5 s.

  • 0 W post detector
  • 9–20 cm wire spacing
  • 60 m typical zone
View TW-100 →
1–3 Razor Coil Layers · 1 Sensing Wire per 0 W Post
1–3 Razor Coil Layers · 1 Sensing Wire per 0 W Post

PerimTaut TW-150

Make Razor Coils Report the Attack

Upgrade passive razor wire into an active alarm line on wall tops (1–3 layers) or freestanding corridors. 0 W tension detectors pair with optional single-loop anti-cut monitoring.

  • 0 W · 1 wire/detector
  • 1–3 wall coil layers
  • Optional loop anti-cut
View TW-150 →
02

Fence and Wall Detection Systems

5 MODELS
2 m Fence Module (0.6–3 m) · Concealed Fiber + Anti-Cut + Cover Tamper
2 m Fence Module (0.6–3 m) · Concealed Fiber + Anti-Cut + Cover Tamper

PerimFence FF-200

Concealed Sensing Inside Architectural Fencing

Preserve clean architectural sightlines while hiding pressure-sensitive fiber inside prefabricated 2 m metal fence modules (0.6–3 m high) to catch ≥30 kg climbs, ≥60 mm bending, cuts, and cover tamper.

  • 2 m modules · 0.6–3 m
  • ≥30 kg / ≥60 mm triggers
  • IP66 zone processor
View FF-200 →
80 km Fence / 100 km Buried · ±4 m Location · Redundant Ring
80 km Fence / 100 km Buried · ±4 m Location · Redundant Ring

PerimOptic FO-700

Pinpoint Intrusions Along 80/100 km Routes

Monitor up to 80 km of fence-mounted or 100 km of buried single-mode fiber from one indoor rack with typical ±4 m accuracy, 1,440 software zones, and ±30 m cut-locating ring resilience.

  • 80 km fence / 100 km buried
  • Typical ±4 m accuracy
  • 1,440 software zones
View FO-700 →
4 × 300 m Passive Zones · Up to 20 km Non-Sensing Lead-In
4 × 300 m Passive Zones · Up to 20 km Non-Sensing Lead-In

PerimOptic FO-750

Four Passive Fence Zones. One Rack 20 km Away.

Cover 4 fence zones of up to 300 m each with 0 W optical cable while placing the 2 W DC/PoE processor up to 20 km away over non-sensing lead-in fiber—backed by local offline alarm buffering.

  • 4 × 300 m sensing zones
  • Up to 20 km lead-in
  • 2 W DC / PoE + buffer
View FO-750 →
Existing Fence + Sensing Cable · Up to 600 m · Within 3 m
Existing Fence + Sensing Cable · Up to 600 m · Within 3 m

PerimVibe VC-600

Add 3 m Breach Location to Your Existing Fence

Attach locating vibration cable to sound chain-link or welded-mesh fences without new civil posts. Monitor up to 600 m per IP66 processor with 3 m location, software zones, and redundant comms.

  • Up to 600 m / processor
  • Within 3 m location
  • Redundant comms
View VC-600 →
Non-Shocking Narrow Field · Up to 7.3 m · 2 × 150 m
Non-Shocking Narrow Field · Up to 7.3 m · 2 × 150 m

PerimField EF-350

A Tall, Narrow Non-Shock Field Along the Edge

Form a controlled ≤0.5 m narrow electrostatic space field up to 7.3 m high on fences (6.1 m freestanding/wall) across 2 × 150 m zones—detecting human approach and metal ladders with 50/60 Hz immunity.

  • 2 × 150 m zones
  • Up to 7.3 m fence height
  • 50/60 Hz grid immune
View EF-350 →
03

Outdoor Microwave Sensors

2 MODELS
Fixed Tx / Rx Pair · 200 m Walk · 150 m Crawl · 100 m Prone
Fixed Tx / Rx Pair · 200 m Walk · 150 m Crawl · 100 m Prone

PerimWave MW-400

Volumetric Protection Across Permanent Open Gaps

Bridge vehicle gates, hangar aprons, rooftops, and double-fence sterile zones with an invisible volumetric beam—covering 5–200 m walking, 5–150 m crawling, and 5–100 m prone targets with DSP and AGC.

  • 200 / 150 / 100 m ranges
  • 1.5 W Tx / 2.6 W Rx
  • 4 Form C relays/pair
View MW-400 →
Tripod + 30 h Battery · 5–200 m Span · ≥2,000 m Radio
Tripod + 30 h Battery · 5–200 m Span · ≥2,000 m Radio

PerimWave MW-450M

Unpack a Cable-Free Perimeter Wherever Work Moves

Set 0.9 kg microwave heads on alloy tripods with 12 V low-temperature lithium batteries (30 h standby) to guard 5–200 m spans and receive wireless alerts ≥2,000 m away at the 4-relay terminal.

  • 5–200 m · 0.9 kg heads
  • 30 h battery standby
  • ≥2,000 m radio alert
View MW-450M →
04

Ground and Surface Sensors

2 MODELS
Twin Buried RF Cables (800 m) · ±1 m Location · Soil / Paving / Water
Twin Buried RF Cables (800 m) · ±1 m Location · Soil / Paving / Water

PerimTerra BF-300

Conceal the Route. Pinpoint Crossings Within ±1 m.

Bury twin RF cables beneath soil, asphalt, concrete, and shallow waterways to project an invisible ~1 m × 2–3 m volumetric corridor—covering up to 800 m per processor with ±1 m multi-target location.

  • Up to 800 m / processor
  • Within ±1 m location
  • Land + waterway route
View BF-300 →
Pad (≥36 mm) · Mat (9/12 mm) · Module (44 mm) · Edge-to-Center Force Balance
Pad (≥36 mm) · Mat (9/12 mm) · Module (44 mm) · Edge-to-Center Force Balance

PerimForce PM-280

Turn Defined Thresholds and Walkways into Sensors

Monitor exact entry surfaces using ≥36 mm pads, ultra-thin 9/12 mm 0 W mats, or 44 mm 1-to-4 modules. Mechanical edge-to-center force compensation delivers ≤1 s response with dual thresholds on pads and modules.

  • Pad / 9 mm Mat / Module
  • Edge-to-center balance
  • ≤1 s alarm response
View PM-280 →
05

Culvert Security Grilles

1 MODEL
Submerged Custom Grille (0 W) · Pry / Cut / Removal → IP66 Unit
Submerged Custom Grille (0 W) · Pry / Cut / Removal → IP66 Unit

PerimGrille FF-250

Close the Perimeter Beneath the Waterline

Custom-fit a corrosion-resistant stainless-steel grille across submerged culverts, drains, tunnels, or vents. Embedded optical fiber (60–80 mm bend), anti-cut lines, and panel tamper switches guard every opening.

  • Fully submerged · 0 W
  • 60–80 mm + cut + tamper
  • Fixed / rail / swing
View FF-250 →
06

Perimeter Security Lighting

1 MODEL
Built-In Accelerometer + 53 lux LED · 3–6 m Spacing · Nearest-Unit ID
Built-In Accelerometer + 53 lux LED · 3–6 m Spacing · Nearest-Unit ID

PerimLume LP-500

Detect the Attack. Light Up the Exact Fence Span.

Every 2.5 W LED luminaire houses an accelerometer to catch cutting, climbing, and lifting—firing instant 53 lux (CRI >70) light or strobe at the nearest fixture and reporting over a 100-unit AES-128 wireless mesh.

  • 53 lux · CRI >70
  • 3–6 m luminaire spacing
  • 100 units / AES-128 gateway
View LP-500 →

04 — Portfolio comparison matrix

Compare the Decisions That Shape Your Design.

Start with Table A to match boundary tasks, physical barrier roles, alarm granularity, and scale. Use Table B to review exact field-versus-room power and control interfaces.

Table A · Primary Selection Matrix
ModelBest-Fit Boundary TaskPhysical BarrierAlarm GranularityKey Selection Facts
TW-100New taut-wire fence or wall/fence-top barrierYes (Barbed array)By zone0 W post detector; on-site pull threshold; 9–20 cm spacing; 60 m typical zone; ≤0.5 s
TW-150Monitored wall-top or ground razor-wire coilsYes (Razor coils)Zone + tamper + cut0 W post detector; 1 wire/detector; 1–3 wall coil layers; optional single-loop anti-cut
FF-200Architectural metal fence with hidden sensingYes (2 m rail modules)By zone + fault0.6–3 m height; ≥30 kg climb, ≥60 mm bend, internal anti-cut, upper-cover tamper
FO-700Long fence, buried, or mixed corridorsSensor layerTypical ±4 m locationUp to 80 km fence / 100 km buried; 1,440 software zones; ±30 m cut-resilient ring
FO-7504-zone compact stations with distant rackSensor layerBy zone (4 zones)4 × up to 300 m passive zones; up to 20 km non-sensing lead-in; 2 W DC/PoE + buffer
VC-600Locating upgrade on existing mesh fencesSensor layerWithin 3 m locationUp to 600 m/processor; multi-event locating; software zones; A/B redundant comms
EF-350Tall, narrow space field on walls, fences, roofsSensor layerBy zone (2 zones)2 × up to 150 m; up to 7.3 m fence (6.1 m wall/ground); non-shock; 50/60 Hz immune
MW-400Permanent open gates, aprons, and roof gapsSensor layerBy link / zone5–200 m walk, 5–150 m crawl, 5–100 m prone; DSP + AGC; stackable and cascadable
MW-450MTemporary maintenance gaps and mobile yardsSensor layerWireless terminal alert5–200 m walk (150 m crawl, 100 m prone); 0.9 kg heads; 30 h battery; ≥2,000 m radio
BF-300Concealed routes across soil, paving, waterwaysSensor layerWithin ±1 m locationUp to 800 m/processor (2 cable pairs); ~1 m × 2–3 m RF field; land + shallow water
PM-280Discrete footsteps at thresholds and walkwaysSensor layerBy surface / zone≥36 mm pad, 9/12 mm 0 W mat, 44 mm module; edge-to-center balance; ≤1 s response
FF-250Submerged culverts, drains, tunnels, and ventsYes (Stainless grille)Zone + cut + removalYear-round submerged 0 W grille; 60–80 mm pry trigger; fixed, rail-guided, or swing
LP-500Fence sensing + camera lighting + deterrenceSensor + luminaireNearest luminaire ID53 lux, CRI >70, 120° beam; 3–6 m spacing; up to 100 units/gateway on AES-128 mesh
Table B · Field Power and Backend Integration
ModelOutdoor / Field Sensing PowerPowered Processing and Control Interfaces
TW-1000 W passive mechanical post switches24 VDC dual-zone I/O (2,000 Vrms isolation) + 9–24 VDC Modbus TCP controller (≥8 relays, battery failover)
TW-1500 W passive mechanical tension switchesPowered zone collection + alarm controller; separate zone intrusion, tamper, and cut dry contacts
FF-200 / FF-2500 W passive optical fiber + cut/tamper loops12–30 VDC (65 mA max) IP66 zone processor; separate NO alarm and fault relays (500 mA, 50 V) + RS-422
FO-7000 W passive 1,550 nm single-mode fiberIndoor rack interrogation processor (>87,000 h MTBF); VMS, PSIM, and alarm platform integration
FO-7500 W passive sensing + 20 km lead-in fiber12–48 VDC or PoE processor (2 W); Ethernet, local offline buffer, 6 Form C relays (1 A, 30 VDC), 2 inputs
VC-600Separate sensor-cable supply: 48 V, 50 WIP66 processor: 10–60 VDC, 2.0 W (2.5 W with comm card); 4 Form C relays, 2 inputs, optional PoE/RS-422/fiber
EF-350Low-frequency field wires driven by processorIP66 processor: 12–48 VDC, <6 W; 4 Form C fail-safe relays, 2 inputs, optional RS-422 and +8 I/O cards
BF-300Active RF field fed via twin coax ports12–48 VDC, <9 W processor (up to 5 units/supply); 4 Form C relays, 2 inputs, optional RS-422/fiber/+8 I/O
PM-280Pads/modules: 12–24 VDC, ≤2 W; Mat: 0 W elementPowered controller over Ethernet or POWER BUS / Modbus RTU; adjustable warning + alarm on pads/modules
MW-400Powered heads: 1.5 W Tx / 2.6 W Rx (12–48 VDC)Onboard digital processing; 4 assignable Form C relays per pair (2 Tx + 2 Rx, 1.0 A, 30 VDC), optional RS-422
MW-450M12 V lithium battery Tx/Rx packs (30 h standby)Wireless terminal (5–24 VDC or 12/24 V battery, 30 h standby); 4 Form C relays + internet PC client
LP-50012–48 VDC wired bus, 2.5 W per luminaireIP65 wireless gateway: 12–48 VDC (0.5 W base / 1.0 W with card), 10 I/O ports, optional PoE/RS-422/fiber

05 — Shortlist decision guide

Three Choices Narrow 13 Models Down to Your Shortlist.

New Monitored Barrier → TW-100 / TW-150 / FF-200 / FF-250 · Existing Sound Fence → FO-700 / FO-750 / VC-600 / LP-500
New Monitored Barrier → TW-100 / TW-150 / FF-200 / FF-250 · Existing Sound Fence → FO-700 / FO-750 / VC-600 / LP-500

01

Build a New Physical Barrier, or Instrument Existing Boundaries?

Specify TW-100, TW-150, FF-200, or FF-250 when your scope needs physical entry resistance and intrusion sensing in one structure. Specify FO-700, FO-750, VC-600, EF-350, or LP-500 when an existing structurally sound fence or wall will carry the sensor layer—or BF-300, PM-280, MW-400, and MW-450M where no fence exists.

Zone Sector Alarm · Pinpoint Coordinate (±4 m / 3 m / ±1 m) · Nearest Luminaire + 53 lux Light
Zone Sector Alarm · Pinpoint Coordinate (±4 m / 3 m / ±1 m) · Nearest Luminaire + 53 lux Light

02

Does Your Team Dispatch by Zone, Exact Meter, or Lit Fence Span?

Zone systems (TW, FF, FO-750, EF-350, MW, PM-280) report a defined perimeter sector matched to fixed camera views. Locating systems pinpoint exact route coordinates—±4 m on FO-700, within 3 m on VC-600, and ±1 m on BF-300—to slew PTZ cameras automatically. LP-500 pinpoints the nearest luminaire and lights the breach on the spot.

0 W Boundary + Indoor Rack (TW / FO / FF) · Field 12–48 VDC Bus (VC / BF / EF / MW-400 / LP) · 30 h Portable Battery (MW-450M)
0 W Boundary + Indoor Rack (TW / FO / FF) · Field 12–48 VDC Bus (VC / BF / EF / MW-400 / LP) · 30 h Portable Battery (MW-450M)

03

Where Can Power and Active Electronics Sit Along Your Site?

Keep 0 W at the boundary in high-EMI or remote corridors using TW-100/150, FO-700/750, or FF-200/250, concentrating power indoors. Use low-wattage 12–48 VDC buses for active field processors (VC-600, BF-300, EF-350, MW-400, LP-500), or deploy 30 h lithium battery kits (MW-450M) where zero site wiring exists.

Terrain slopes, road/water crossings, vehicle gates, and dredging maintenance access are combined across models in multi-zone site proposals.

06 — End-to-end alarm architecture

Connect Every Boundary Action to a Usable Operator Alarm.

Across the portfolio, field hardware captures mechanical force, optical phase/intensity shift, surface pressure, or electromagnetic disturbance—then converts that physical event into dry-contact relays, RS-422 serial links, Modbus TCP, or Ethernet events matched to your VMS, PSIM, or alarm panel.

Fig. 02.6 — Four-stage perimeter response pipeline (Detect → Process → Report → Respond) showing distinct mechanical, optical, active-field, and wireless-lighting branches.
Fig. 02.6 — Four-stage perimeter response pipeline (Detect → Process → Report → Respond) showing distinct mechanical, optical, active-field, and wireless-lighting branches.

01

PerimTaut Mechanical Chain

0 W post dry contacts → 24 VDC optically isolated zone I/O → Modbus TCP controller (≥8 relays + battery failover)

02

PerimOptic Passive Fiber Chain

0 W fence/buried single-mode fiber → indoor laser interrogation unit → zone relays / Ethernet VMS integration

03

PerimLume Wireless Lighting Chain

12–48 VDC accelerometer luminaires → 2.4 GHz AES-128 self-healing mesh → IP65 gateway processor (PoE / RS-422 / fiber)

07 — Next step

Turn Your Model Shortlist into a Preliminary Perimeter Plan.

Send your boundary layout, approximate segment lengths, and any gates, culverts, or existing fences you need to cover. Our engineering team will map a preliminary zone proposal and prepare an equipment supply quotation around the right models.