Perimeter Intrusion Detection Systems (PIDS)
High-Reliability Perimeter Intrusion Detection with Minimal Upkeep
PerimSense supplies perimeter intrusion detection systems across six boundary zones, led by our PerimTaut passive taut-wire barriers—engineered for dependable pull-and-cut detection, on-site adjustable pull thresholds that filter out animal and plant contact, competitive pricing against equivalent taut-wire systems, and fast dispatch.
- Passive Sensor Frontends
- 0 W in Field PerimTaut and passive fiber sensors need no field power cabling—unaffected by electromagnetic and radio-frequency interference (EMI/RFI)
- On-Site Threshold Tuning
- Low Nuisance PerimTaut force thresholds adjust on site to filter out animal and plant contact while keeping pull-and-cut alarms dependable
- Material-Based Sensing
- Low Upkeep PerimTaut's material-based core sensing structure rarely suffers damage while protective materials remain intact, easing long-term upkeep
- Same-Tier Taut-Wire Value
- Fast Dispatch PerimTaut barriers offer competitive pricing against equivalent high-security taut-wire systems with responsive production and dispatch
01 — Boundary zones
Select Perimeter Sensors by Boundary Zone
Six physical zones of a facility perimeter and the intrusion detection systems engineered for each boundary. Select any zone to inspect its deployment layer and compatible models.
-
01 / NIGHT DETERRENCE
Perimeter Security Lighting
Fence-line LED luminaires combining camera-ready perimeter lighting with built-in impact alarm strobe.
LP-500 → -
02 / OUTER BARRIERS
Taut-Wire Systems
Self-regulating taut-wire fences and monitored razor coils where the physical barrier is the sensor.
TW-100 · TW-150 → -
03 / FENCE LINES
Fence Detection Systems
Optical fibers, locating vibration cables, security fencing, and wall-top field arrays for perimeter lines.
FF-200 · FO-700 · FO-750 · VC-600 · EF-350 → -
04 / ACCESS GATES
Outdoor Microwave Sensors
Fixed bistatic beams and battery-powered portable microwave guards for vehicle gates and open spans.
MW-400 · MW-450M → -
05 / WATERWAYS
Culvert Security Grilles
Submersible stainless-steel optical-fiber grilles blocking intrusion through storm drains and water trenches.
FF-250 → -
06 / GROUND BUFFERS
Buried Ground Sensors
Invisible underground RF volumetric cables and covert pressure modules beneath turf, gravel, or pavers.
BF-300 · PM-280 →
02 — Site deployment map
Six Sensor Categories Across One Protected Site
One protected site, taken apart layer by layer: overhead lighting, ground barriers and gates, and buried sensors under land and water.
Illustrative site layout. Zone lengths and controller counts are configured per project.
03 — Flagship Series: PerimTaut TW-100 · TW-150
Self-Regulating Passive Taut-Wire for High-Security Barriers
Each PerimTaut taut-wire system pairs a physical delay barrier with unpowered mechanical detectors at the post, connected to powered zone alarm and communications equipment. On-site adjustable pull thresholds filter out animal and plant contact, while self-adjusting mechanical compensation offsets slow thermal and soil drift—delivering dependable pull-and-cut alarms with minimal nuisance dispatches.
Why PerimTaut
-
On-site adjustable pull thresholds filter out animal and plant contact while retaining reliable detection of pulls above the set threshold and wire or coil cutting.
-
Unpowered post detectors contain zero circuit boards or strain gauges, operating unaffected by electromagnetic and radio-frequency interference (EMI/RFI), while on-site force-threshold tuning filters out animal and plant contact to cut nuisance alarms.
-
An internal self-adjusting structure compensates for gradual thermal expansion, contraction, and slow ground movement, helping keep sensitivity consistent across seasons with low routine upkeep.
-
PerimTaut barriers offer competitive pricing against equivalent high-security taut-wire systems, zero post power, and fast dispatch for project schedules.
-
Because detection relies on the physical properties of its materials rather than fragile field electronics, the core sensing structure rarely suffers damage as long as its protective materials remain intact—keeping routine detector upkeep minimal.
Integration path
How PerimSense Hardware Integrates into Existing Security Panels
-
Step 01 · Field Sensing Layer
Unpowered or Active Barrier Sensors
Deploy unpowered dry-contact posts (TW-100, TW-150), passive optical fibers (FF-200, FF-250, FO-700, FO-750), or dedicated active field sensors.
-
Step 02 · Powered Backend Equipment
Zone Modules, Controllers, and Processors
Supply electrical power to zone alarm modules, alarm controllers, optical interrogators, or active field processors according to your site wiring and enclosure layout.
-
Step 03 · Panel Handshake
Configuration-Matched Alarm Outputs
Connect to existing alarm panels, PLCs, and security management platforms through zone switch or relay outputs and controller-specific communication interfaces matched to the selected model.
04 — Solutions by facility
Perimeter Security Solutions by Facility Environment
Combine primary barrier sensors with gate, ground, and culvert detection matched to your site layout and operating climate.
05 — Engineering guides
Technical Guides for Sensor Selection
Evaluate mechanical damping principles, field-to-cabinet power boundaries, and harsh-climate installation practices before writing your tender specification.
-
Mechanical Damping vs. Electronic Strain-Gauge Taut-Wire
Compare unpowered mechanical dry-contact posts against active strain-gauge transducers across lightning exposure, thermal drift, and upkeep.
Read technical comparison -
Passive Sensing Elements vs. System Power Architecture
Review which barrier elements run with zero field power and where centralized cabinet power feeds zone modules, controllers, and interrogators.
Read power boundary guide -
Security Fence Installation and Harsh-Environment Upkeep
Plan anchor post spacing, wall-top mounting, coastal salt-mist protection, and routine inspection across extreme heat, frost, and wind.
Read installation guide
06 — Start your project
Get a Preliminary Zone Proposal or Product Information