PerimVibe VC-600 · Locating Fence-Mounted Vibration Cable Detection

Keep Your Existing Fence. Locate Breaches Within 3 m Across 600 m.

Turn standing chain-link, welded-mesh, or palisade fencing into a precise locating perimeter without civil demolition. PerimVibe VC-600 monitors up to 600 m per IP66 processor, pinpoints simultaneous cuts and climbs within 3 m via high-speed DSP, and sustains protection after a cable cut through redundant communication.

Share your boundary layout for a preliminary zone proposal and equipment supply quote.
Software-Defined Zones + Redundant A/B Link01020304053 m3 m
01Sensing-cable power supply · 48 V, 50 W
02VC-600 processor · IP66 (10–60 VDC, 2.0–2.5 W)
03Breach A located within 3 m
04Existing fence retained · Up to 600 m per processor
05Breach B located within 3 m
Software-defined zones + redundant A/B link
Existing-Fence Upgrade
600 m
Monitored fence length per processor with zero civil demolition
Camera-Ready Precision
3 m
Intrusion location accuracy across simultaneous multi-point breaches
Cut-Survivable Reporting
A/B Dual-Path
Redundant communication keeps perimeter protection active after cuts
Outdoor-Hardened Processor
IP66
Draws 2.0–2.5 W across -40°C to +70°C right on the fence
01 — Key capabilities

Twelve Reasons Established Facilities Upgrade with VC-600

01

Pinpoint Intrusions on Existing Fences

01

600 m Single-Processor Reach

Monitor up to 600 m of existing perimeter fencing from one compact processor.

02

3 m Breach Pinpointing

Locate fence cutting, climbing, and pulling within 3 m for instant camera slew.

03

Simultaneous Multi-Point Tracking

Resolve multiple concurrent intruders along the fence without masking secondary breach points.

04

Software-Defined Operational Zones

Map flexible alarm sectors in software around gates, buildings, and camera presets.

02

Defeat Weather Noise and Cable Cuts

05

High-Speed DSP Discrimination

Sample reflected cable signals at high speed to separate breaches from wind noise.

06

Cut-Resilient Redundant Links

Maintain active perimeter protection after a cable cut using dual-ended A/B communication.

07

IP66 -40°C to +70°C Enclosure

Mount IP66 processors directly outdoors across -40°C to +70°C weather extremes.

08

TVS and Gas-Tube Surge Defense

Protect power and I/O ports with integrated transient suppression and gas discharge tubes.

03

Match Site Power, Fiber, and Relays

09

Multi-Fence Direct Retrofit

Attach sensing cable directly onto chain-link, welded-mesh, or palisade fences without trenching.

10

PoE, RS-422, or 10 km Fiber

Network processors via PoE Ethernet, RS-422, 2.2 km multimode, or 10 km single-mode fiber.

11

4 Onboard + 4 Expansion Relays

Drive local panels via 4 onboard relays plus optional 4-relay and 4-input cards.

12

2.0–2.5 W Host + 48 V Cable Power

Run 10–60 VDC processors at 2.0–2.5 W alongside a 48 V, 50 W cable supply.

02 — Operating principle

How Minute Cable Deformation Pinpoints Fence Breaches Within 3 m

Attached directly along up to 600 m of fence fabric per processor and energized by a 48 V, 50 W sensing-cable supply, the VC-600 cable responds whenever an intruder cuts, climbs, or pulls the barrier.

That mechanical vibration causes minute physical deformation in the sensing cable, generating reflected electrical signals along the span.

Fence Vibration and Cable Deformation
01
Fence vibration and cable deformation
Cut, climb, or pull along up to 600 m span
High-Speed Reflected-Signal DSP
02
High-speed reflected-signal DSP
Separates breach signatures from wind and rain
3 m Coordinate + Software Zone
03
3 m coordinate + software zone
Simultaneous multi-event locating

Drawing just 2.0–2.5 W on 10–60 VDC, the IP66 processor samples those reflections at high speed, applies digital signal processing (DSP) to reject wind and rain noise, locates simultaneous intrusions within 3 m, and assigns each event to its software-defined zone.

03 — Cut-resilient communication

A Snipped Fence Cable Does Not Silence Your Perimeter.

Security directors often hesitate to mount copper sensing cables on exposed perimeter fences because they worry one deliberate wire-cutter snip will blind hundreds of meters of boundary protection.

VC-600 eliminates single-path vulnerability with a redundant communication architecture across dual A and B side Tx/Rx links—supported on RS-422 copper, 2.2 km multimode fiber, 10 km single-mode fiber, and networked Ethernet layouts.

Normal Closed-Path Operation
State A
Normal closed-path operation
Up to 600 m per processor · Full fence active
Cable connector / cable terminator / 48 V, 50 W supply
Cable Cut + Redundant Path Active
State B
Cable cut + redundant path active
Cut located within 3 m
A/B Tx/Rx Backup Route Sustains Protection
A/B Tx/Rx backup route sustains protection

If a cable is severed, the processor immediately reports the cut event within 3 m while routing ongoing alarm traffic over the redundant path so remaining fence sections stay actively protected.

04 — Field deployment

Engineered for the boundary you operate.

Scenario 01 · Brownfield Fence Modernization

Turn Standing Industrial and Rail Fences into Smart Boundaries Without Civil Work

Airports, logistics hubs, and chemical parks surrounded by intact fences cannot afford civil demolition or weeks of open-perimeter construction just to add intrusion alarms. VC-600 fastens sensing cable directly onto existing chain-link, welded-mesh, or palisade fence panels across up to 600 m per processor. Software-defined zones let security teams align alarm boundaries with gates, loading bays, and guard posts—and resize sectors anytime without moving field hardware.

Plan this perimeter →
Direct cable retrofit
Existing Fence Structure Retained
Existing fence structure retained
VC-600 sensing cable attached
Up to 600 m coverage
Software-defined zones Z-01 / Z-02 / Z-03
04 — Field deployment

Engineered for the boundary you operate.

Scenario 02 · 3 m Camera and Guard Dispatch

Direct PTZ Cameras to the Exact 3 m Fence Panel—Even Under Coordinated Attack

An unlocated alarm spanning a 600 m fence sector leaves operators sweeping PTZ cameras blindly across hundreds of panels while an intruder disappears into the yard. VC-600 pinpoints every cutting, climbing, or pulling event within 3 m so cameras slew immediately to the exact breach panel. When multiple intruders strike different spots simultaneously, the processor locates and reports each event independently without masking secondary entries.

Plan this perimeter →
Simultaneous multi-point tracking across a 600 m fence span
600 m Monitored Fence Span
600 m monitored fence span
Simultaneous event 01
Within 3 m
Simultaneous event 02
Within 3 m
Direct PTZ preset verification
04 — Field deployment

Engineered for the boundary you operate.

Scenario 03 · High-Wind and Transport Perimeters

Separate Sharp Cut and Climb Signatures from Wind, Rain, and Passing Trains

Fences bordering open airfields, coastal yards, and railway corridors vibrate constantly in gusting wind, heavy rain, and passing vehicle rumble—overwhelming simple threshold sensors with false alarms. VC-600 samples reflected cable waveforms at high speed and applies digital signal processing (DSP) to distinguish localized cutting, climbing, and pulling mechanics from distributed environmental motion. Security operators receive verified 3 m breach locations instead of storm chatter.

Plan this perimeter →
Conceptual DSP signal discrimination
Distributed Wind and Rain Fence Rattle
Distributed wind and rain fence rattle
Localized cut / climb / pull reflection
High-speed DSP signature analysis
Verified 3 m alarm output
04 — Field deployment

Engineered for the boundary you operate.

Scenario 04 · Multi-Media Perimeter Networking

Link Perimeter Processors Over PoE Ethernet, RS-422, or 10 km Single-Mode Fiber

Connecting perimeter processors across sprawling chemical complexes, rail corridors, and multi-building campuses fails when hardware locks integrators into short copper runs. VC-600 adapts to your backbone with optional PoE-capable Ethernet, dual-ended A/B RS-422 cards, 820 nm ST multimode fiber cards up to 2.2 km, or 1,310 nm ST 9/125 μm single-mode fiber cards up to 10 km—and networks seamlessly alongside PerimTerra BF-300, PerimWave MW-400, and PerimField EF-350.

Plan this perimeter →
Four VC-600 communication card choices
Ethernet Card01020304
Option 01
Ethernet card
Optional PoE
Option 02
RS-422 card
A/B Tx/Rx
Option 03
820 nm ST multimode fiber
Up to 2.2 km, A/B
Option 04
1,310 nm ST 9/125 μm single-mode fiber
Up to 10 km, A/B
Unified integration
BF-300 / MW-400 / EF-350
04 — Field deployment

Engineered for the boundary you operate.

Scenario 05 · Outdoor Hardware, I/O Expansion, and Power Sizing

Mount IP66 Surge-Protected Processors Outdoors with Expandable Relay and Supervised I/O

Outdoor perimeter boxes fail prematurely when processors lack weather sealing, lightning protection, or local I/O capacity for nearby gate contacts. VC-600 combines an IP66 (-40°C to +70°C) enclosure and full TVS + gas-discharge surge protection with 4 assignable Form C relays (1 A, 30 VDC; 0.125–10 s adjustable activation time), 2 self-test/auxiliary inputs, plus optional +4 relay and +4 supervised-input cards—backed by transparent sizing: 2.0–2.5 W (10–60 VDC) per processor and 48 V, 50 W for sensing-cable power.

Plan this perimeter →
VC-600 IP66 hardware and power budget diagram
IP66 Enclosure
IP66 enclosure
-40°C to +70°C · TVS + GDT surge protection
Processor power: 10–60 VDC
2.0–2.5 W
Sensing-cable supply
48 V, 50 W
4 onboard Form C relays
1 A, 30 VDC · 0.125–10 s hold
2 self-test / aux inputs + optional +4 DO / +4 supervised DI cards
05 — System architecture and bill of subsystems

Clear Hardware, Power, and Communication Roles Along Every 600 m Section

PerimVibe VC-600 upgrades existing fence lines using active fence-mounted sensing cable, compact IP66 field processors, dedicated cable power, and redundant communication links—giving civil, electrical, and security teams an unambiguous scope split.

Solid: sensing / power · Dashed: communication
01 FIELD ASSEMBLY600 m · copper cable
Fence Sensing Section · Up to 600 m per Processor
01
Fence sensing section · Up to 600 m per processor
3 m location
02
Cable connector + end cable terminator
03
Sensing-cable power supply
48 V, 50 W
02 PROCESSING / CONTROL10–60 VDC · 2.0–2.5 W
VC-600 Processor · IP66
04
VC-600 processor · IP66
10–60 VDC · 2.0 W / 2.5 W with comm card
05
Redundant A/B link
PoE Ethernet / RS-422 / 2.2 km MMF / 10 km SMF
03 SECURITY MANAGEMENTAlarm dispatch + camera cue
Security Management System / Control Center
06
Security management system / control center

System components and trade interfaces

Subsystem Layer
Components Included
Power Status
Location and Trade Scope
01 · Fence Sensing Cable Assembly
VC-600 locating vibration sensing cable (up to 600 m per processor), splice cable connectors, end-of-line cable terminators, and UV-resistant fence fasteners
Powered via 48 V, 50 W sensing-cable power supply
Attached directly to existing perimeter fence fabric · Fence and low-voltage crew
02 · VC-600 IP66 Locating Processor
Outdoor DSP locating processor (-40°C to +70°C, IP66) with 4 onboard Form C relays (1 A, 30 VDC; 0.125–10 s), 2 self-test/aux inputs, and TVS + gas-discharge surge protection
Powered (10–60 VDC input or optional PoE; 2.0 W base, 2.5 W with comm card)
Mounted at perimeter fence post or field cabinet · SI installation
03 · Redundant Communication Cards
Choice of Ethernet card (optional PoE), RS-422 card (A/B Tx/Rx), 820 nm ST multimode fiber card (up to 2.2 km, A/B), or 1,310 nm ST 9/125 μm single-mode fiber card (up to 10 km, A/B)
Powered via processor (+0.5 W card draw included in 2.5 W total)
Installed inside VC-600 processor housing · SI network termination
04 · Optional I/O Cards and Platform
Optional +4 Form C relay card (1 A, 30 VDC), optional +4 configurable supervised-input card, and central security management platform integration
Powered (Control room rack / field processor bus)
Field processor slot and central security control room · SI commissioning
06 — Technical specifications

PerimVibe VC-600 Full Engineering Specifications

Detection and Locating
Parameter
Standard Specification
Sensing Principle
High-speed sampling and digital signal processing (DSP) of reflected signals from fence-mounted vibration cable
Coverage per Processor
Up to 600 m of fence monitoring and locating per processor
Intrusion Location Accuracy
Within 3 m
Multi-Event and Zoning
Simultaneous detection and location of multiple intrusions; flexible software-defined zones
Detected Actions and Fences
Cutting, climbing, pulling, or damaging the fence; compatible with diverse existing fence structures
Electrical and Surge Protection
Parameter
Standard Specification
Processor Input Voltage and Power
10–60 VDC input; 2.0 W (processor only), 2.5 W (processor with communication card)
Sensing-Cable Power Supply
48 V, 50 W
Lightning and Surge Protection
Transient voltage suppression (TVS) diodes and gas discharge tubes across all inputs, outputs, and power
Onboard and Expansion I/O
Parameter
Standard Specification
Onboard Relay Outputs
4 Form C relays rated 1 A at 30 VDC; user-assignable functions per relay
Relay Activation Hold Time
Adjustable from 0.125 s to 10 s
Onboard Inputs
2 self-test inputs (1 per side); convert to 2 auxiliary dry-contact inputs in network mode
Optional I/O Expansion Cards
Relay output card: +4 Form C relays (1 A, max 30 VDC); universal input card: +4 supervised inputs with configurable thresholds
Communication and Environment
Parameter
Standard Specification
Ethernet and Copper Options
Ethernet card with optional PoE support; RS-422 network card with A and B side Tx/Rx connections
Optical Fiber Communication Cards
Multimode RS-422 fiber card: ST, 820 nm, A/B Tx/Rx, up to 2.2 km; single-mode RS-422 fiber card: ST, 9/125 μm, 1,310 nm, A/B Tx/Rx, up to 10 km
Cut Resilience and Multi-System Link
Redundant communication continues perimeter protection after a cable cut; integrates with BF-300, MW-400, and EF-350
Enclosure, Temp and Humidity
IP66 outdoor enclosure; -40°C to +70°C operating temperature; 0–95% RH, non-condensing

Above values reflect standard product technical specifications. Multi-processor chaining, 48 V cable power placement, and redundant communication ring media are finalized against your fence layout during project design.

07 — Engineering FAQ

Common Questions Before Specifying VC-600

01When should we choose VC-600 vibration cable versus FO-750 or FO-700 fiber-optic fence sensors?

Choose PerimVibe VC-600 when upgrading 300 m to several kilometers of standing fence where 3 m breach location, software-defined zones, outdoor IP66 processors, and flexible PoE, RS-422, or fiber networking fit your power layout. If your fence perimeter must remain 0 W unpowered due to flammable gas zoning or extreme HV EMI, select PerimOptic FO-750 (4 × 300 m zones) or PerimOptic FO-700 (up to 80 km fence locating).

02How should electrical engineers budget field power for VC-600 processors and sensing cables?

Keep the two figures separate in your power schedule: each VC-600 processor accepts 10–60 VDC (or optional PoE) and consumes just 2.0 W alone or 2.5 W with a communication card, while the sensing-cable power supply is rated at 48 V, 50 W. Our team maps exact power injection points on your perimeter drawing.

03How does VC-600 scale past 600 m and integrate sliding gates along an industrial perimeter?

Multiple 600 m processors chain seamlessly across multi-kilometer fences via PoE Ethernet, RS-422, 2.2 km multimode fiber, or 10 km single-mode fiber with A/B redundancy. At vehicle gates, wire gate contacts directly into the processor's 2 auxiliary dry-contact inputs (or the optional +4 supervised-input card), or pair the gate span with a PerimWave MW-400 microwave link (5–200 m).

04Does the 0.125–10 s specification describe intrusion detection latency or relay output hold time?

VC-600 performs real-time intrusion detection and 3 m location through high-speed signal sampling and DSP analysis. The 0.125–10 s setting defines the adjustable activation hold duration for the 4 onboard Form C relays (1 A, 30 VDC), ensuring reliable contact latching across diverse third-party alarm panels and NVR inputs.

08 — Next step

Get a Preliminary VC-600 Retrofit Layout and Equipment Supply Quote

Share your existing fence length, panel type, and network preference. Our engineering team will map 600 m processor sections, 48 V power placement, redundant communication cards, and prepare an equipment supply quotation.

01Total existing fence length (sized in up to 600 m processor sections) and gate openings
02Fence construction and height (chain-link, welded-mesh, or steel palisade)
03Preferred communication link (PoE Ethernet, RS-422, 2.2 km multimode, or 10 km single-mode fiber)
04Field power availability (10–60 VDC / PoE for processors and 48 V, 50 W cable supply points)